By Ben Erkens, December 2005
Our JVC VHS-/HDD video-recorder suffered from memory-loss. Increasingly, the
blue HDD indicator on the front panel failed to illuminate after switching on
the VCR.
The JVC service department in the Netherlands advised me to unplug the power
cord for a least an hour, after which it should be fine again.
We had to repeat this exercise more and more often, so I called JVC again and
asked if there was service menu inside. Also, could I defragment the hard disk?
No, apparently these things were not possible.
On Andy Cippico’s website I found some information about problems with the HDS1
and the operating software that is installed on the HD. That worried me; what
would happen if my HD failed? What would it cost when JVC replace the HD?
I read about the drive geometry, which is critical: “replace the HD with an
identical type”.
Inside the HDS-4 I found a Maxtor 80GB “DiamondMax 16”, type no. 4R080L0, ATA/133. On the Maxtor there was an information label:
158.816 sectors, 16.383 cylinders, 16 heads and 63 bytes/sector.
A suitable clone was found: the Maxtor 80GB “DiamondMax Plus 9”, available with a 2MB (p/n 6Y080L0) or a 8MB cache buffer inside (p/n 6Y080P0). I ordered the 8 MB version and there it was, on the bench, next to the old HD from JVC.
Now I needed software to clone the HD. I already had a copy of Ghost 2003 for
Windows, Partition Magic 6.0, Drive Copy 4.0 and Ghost 9.0 for Windows, but none
of them let me physically copy (clone) the HD1. All those programs
were looking for a partition, but that was invisible due to the special JVC
format on the HD.
So I read about DFSEE2 in Andy’s manual “Cloning
and Backing up the JVC HM-HDS1 Hard Drive”. Looking on the internet, I found
a trial version on the website of DFSEE.
I installed the old HD as a Master, the new HD as a Slave and started DFSEE.
It took more then 18 hours (65.935 seconds ;-) to clone the HD, and the program ended with the warning: Master boot record is not valid, no partition recognized
Ignoring this, I disconnected the 2 drives from the PC, moved the jumper on the
new drive back to Master and connected it to the JVC.
Yes, there was light, the magic blue light on the front panel, indicating the
system was healthy.
I hope this short story will help others with their JVC problems.
A word of advice: when your HDD-VCR starts giving problems, replace the HD
yourself, before you are unable to clone it!
Ben Erkens , ben(at)berkens.demon.nl
Editor's notes:
1 Ghost and Drive Image will clone the drive, but you have to use
RAW mode.
2 DFSEE is quite difficult for the novice to use. I now recommend using
Ghost. Get it here
| Technical Home | Guestbook | Forums | Home |